Selected:

Vacuum regulator M 50…

Vacuum regulator M 50 C

Capacity up to 200 kg/h

Vacuum Regulators are a part of chlorination system, designed to feed gas chlorine and with minor alterations also for other gases, working on the indirect vacuum principle.

General Info

GENERAL

Vacuum Regulators M 50 C are designed to feed larger amounts of gas chlorine and with minor alterations also for other gases, working on the indirect vacuum principle.

M 50 C regulators consist of:
inlet pressure valve
regulator head
pressure gauge
Optionally, they can be equipped with:
drip-leg and heater
y-strainer
chlorine gas filter

OPERATION PRINCIPLE

Gas pressure (Cl2) builds up only at the yoke adapter of the regulator. The inlet valve prevents gas from entering the system without control. When the ejector has generated enough vacuum to overcome the force of the check valve, gas chlorine travels along the vacuum line through the flow meter and the rate valve to the ejector, where it thoroughly mixes with water.

Technical Data

Gas types:

C=Cl2
S=SO2
CO2=CO2
N=NH3

Accuracy:
Within 4% of flow

Operating range:
20 : 1

Weight :
19 kg

Dimensions:
673 x 488 x 179 mm

Connections
Vacuum (up to 15m):
60 kg/h – d50 – 2″
80 kg/h – d50 – 2″
120 kg/h– d50 – 2″
160 kg/h – d50 – 2″
200 kg/h – d50 – 2″
For larger vacuum lines, see table: Chlorine vacuum line size requirements Chlorine_vacuum_line_size_requirements.pdf

Pressure:
Flange connection D3/4’’ NP16 DN20 (DIN2633)

Other connections on request!